HOTSTART
-
grid
-
list
Showing 1–18 of 26 results
- grid
- list
Showing 1–18 of 26 results
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
Battery Heating Pad
د.إ0.000Availability: In stockOut of stock
Battery heater not recommended for nickel cadmium batteries.
When batteries are placed in an insulated battery box, a thermostat is recommended to sense battery box temperature to prevent overheating the battery. -
Battery Wraps
د.إ0.000Availability: In stockOut of stock
Prolong the life of your battery with HOTSTART thermal battery wraps with or without thermostat.
• Durable, fire-retardant vinyl cover that resists oils and acids.
• All standard battery pads and battery wraps come with 6’ (1.8m) grounded cord and plug.
• Fast, easy installation.
• Boosts battery cranking power as much as 75%. -
CB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
-
CL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
- Adjustable 90° – 130° (32°C – 54°C)
- Fixed Thermostat:
-
CLM Model
د.إ0.000Availability: In stockOut of stock
-
Heating Fluid: Engine coolant (50% glycol/50% water
Power: 27-36kW
Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 120°F (50°C)
High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.9 gal (3.5L)
Pump Power: 0.75Hp (0.55kW)
-
-
CMM Model
د.إ0.000Availability: In stockOut of stock
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Power: 12 – 24kW
- Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
- Temperature Controller: Adjustable 32°-212°F (0°-100°C)
- Temperature Setting: 120°F (50°C)
- High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
- High Limit Temperature Setting: 195°F (90°C)
- Fluid Capacity: 0.8 gal (3.0L)
- Pump Power: 0.5Hp (0.37kW)
-
COL Model
د.إ0.000Availability: In stockOut of stock
COL System Features
Weathertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
Flow detection switches for fail-safe operation
Pressure switch for automatic operation
Universal mounting for varied mounting configurations
100° to 120°F thermostat for coolant and 80° to 100°F oil thermostat
On/Off switch for coolant and oil heating operations -
CSM Style A
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CSM was developed to preheat diesel and gas engines for stationary land power, marine, large mining and construction equipment.
-
CSM Style B
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CSM was developed to preheat diesel and gas engines for stationary land power, marine, large mining and construction equipment.
-
CTM Model
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CTM was developed to preheat diesel and gas engines for stationary land power, marine and construction equipment.
-
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27 -
EE Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C
Adjustable 90° – 130° (32°C – 54°C)
-
Immersion Heater
د.إ0.000Availability: In stockOut of stock
TEMPERATURE RANGE CONTROL ON OFF 60°F (16C) 80°F (27C) HLC-6 80°F (27C) 100°F (38C) HLC-8 100°F (38C) 120°F (49C) HLC-10 ELECTRICAL RATING 15 Amps at 120 Vac 10 Amps at 240 Vac 10 Amps at 277 Vac -
Lube Oil Heater (Weathertight)
د.إ0.000Availability: In stockOut of stock
Temperature Range Code ON OFF 60°F (16C) 80°F (27C) 6 80°F (27C) 100°F(38C) 8 100°F(38C) 120°F (49C) 10 -
OCLA System
د.إ0.000Availability: In stockOut of stock
SPECIFICATIONS
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 230, 400 V
Temperature Controller: Adjustable 0 – 100 °C (32 – 212 °F)
Temperature Setting: Oil 40 °C (105 °F) / Coolant 50 °C (120 °F)
High-Limit Temperature Control: Adjustable 0 – 100 °C (32 – 212°F)
High-Limit Temperature Setting: 90 °C (195 °F)
Fluid Capacity: 3.8 L (1 gal)
Pump Power: Oil 0.75 – 2.25 kW (1 – 3 Hp)
Coolant 0.75 kW (1 Hp) -
OCLE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 208, 240, 440 – 480, 575 – 600 V
Temperature Controller: Adjustable 32 – 212 °F (0 – 100 °C)
Temperature Setting: Oil 105 °F (40 °C) / Coolant 120 °F (50 °C)
High-Limit Temperature Control: Adjustable 32–212 °F (0 – 100 °C)
High-Limit Temperature Setting: 195 °F (90 °C)
Fluid Capacity: 1 gal (3.8 L)
Pump Power: Oil 1 – 3 Hp (0.75 – 2.25 kW) Coolant 1 Hp (0.75 kW)
Maximum Pressure: 100 psi (690 kPa) -
OCSM Model
د.إ0.000Availability: In stockOut of stock
- Primary Heating Fluid: Engine Coolant
- Secondary Heating Fluid: Engine Oil
- Heat Power: 6, 9, 12 kW
- Voltage Range: 1 or 3 Phase 208 – 600V (50 or 60 Hz)
- Temperature Controller: Fixed 100 – 120 °F (38 – 49 °C)
- High-Limit Temp. Control: Fixed 165 – 205 °F (74 – 96 °C)
- Fluid Capacity: Coolant – 0.7 gal (2.6L)
- Oil – 0.2 gal (0.8L)
- Pump Power: Coolant – 0.04 Hp (0.03 kW)
- Oil – 0.33 Hp (0.25 kW)
-
OSE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 480V/60Hz/3ph (Contact HOTSTART for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 0.75, 2Hp (0.56, 1.5 kW)