HOTSTART’s OSE is a complete oil heating system designed to heat and circulate oil in small compressors. The OSE is also designed to prelube the compressor frame in applications with flow requirements up to 11GPM.
The heating system pulls oil from the compressor sump using a positive displacement oil pump. Oil is heated and circulated through the compressor lubricating system.
This eliminates the need for a supplemental prelube pump. Prelubing compressors with heated oil reduces condensation and supplies consistent pressure to the lubricating system with minimal variation in viscosity.
Compressors can benefi t from prelubing in both cold climates and high humidity climates where temperature variations can result in damaging condensation.
OSE Model
د.إ0.000
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 480V/60Hz/3ph (Contact HOTSTART for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 0.75, 2Hp (0.56, 1.5 kW)
Product Type | Genset |
---|---|
Oil Heater | |
Power (Heater) |
QR Code
Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
SB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable 90° – 130°F (32°C – 54°C)
-
OSX Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 240V/60Hz/1ph, 480V/60Hz/3ph (Contact TCT for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 1, 2Hp (0.75, 1.5 kW) -
CLM Model
د.إ0.000Availability: In stockOut of stock
-
Heating Fluid: Engine coolant (50% glycol/50% water
Power: 27-36kW
Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 120°F (50°C)
High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.9 gal (3.5L)
Pump Power: 0.75Hp (0.55kW)
-
-
OCLE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 208, 240, 440 – 480, 575 – 600 V
Temperature Controller: Adjustable 32 – 212 °F (0 – 100 °C)
Temperature Setting: Oil 105 °F (40 °C) / Coolant 120 °F (50 °C)
High-Limit Temperature Control: Adjustable 32–212 °F (0 – 100 °C)
High-Limit Temperature Setting: 195 °F (90 °C)
Fluid Capacity: 1 gal (3.8 L)
Pump Power: Oil 1 – 3 Hp (0.75 – 2.25 kW) Coolant 1 Hp (0.75 kW)
Maximum Pressure: 100 psi (690 kPa) -
CMM Model
د.إ0.000Availability: In stockOut of stock
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Power: 12 – 24kW
- Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
- Temperature Controller: Adjustable 32°-212°F (0°-100°C)
- Temperature Setting: 120°F (50°C)
- High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
- High Limit Temperature Setting: 195°F (90°C)
- Fluid Capacity: 0.8 gal (3.0L)
- Pump Power: 0.5Hp (0.37kW)
-
COL Model
د.إ0.000Availability: In stockOut of stock
COL System Features
Weathertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
Flow detection switches for fail-safe operation
Pressure switch for automatic operation
Universal mounting for varied mounting configurations
100° to 120°F thermostat for coolant and 80° to 100°F oil thermostat
On/Off switch for coolant and oil heating operations -
-
Lube Oil Heater (Weathertight)
د.إ0.000Availability: In stockOut of stock
Temperature Range Code ON OFF 60°F (16C) 80°F (27C) 6 80°F (27C) 100°F(38C) 8 100°F(38C) 120°F (49C) 10 -
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27
Reviews