Use a thermostat with all lube oil heaters to protect the oil from overheating. Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times.
Lube Oil Heater (Weathertight)
د.إ0.000
Temperature Range | Code | |
ON | OFF | |
60°F (16C) | 80°F (27C) | 6 |
80°F (27C) | 100°F(38C) | 8 |
100°F(38C) | 120°F (49C) | 10 |
Power (Heater) | 50 Watts, 75 Watts, 125 Watts, 150 Watts, 225 Watts, 300 Watts, 450 Watts, 500 Watts |
---|---|
Oil Heater | |
Product Type | Genset |
QR Code

Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
CL Model (Watertight)
د.إ0.000Availability: In stockOut of stock
Pressure switch or relay for automatic operation
Universal mounting for varied mounting configuration
100° to 120°F fixed thermostats
On/Off switch for manual control
Watertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
External motor protective switch reset button -
-
CB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
-
Silicone Hot Pad
د.إ0.000Availability: In stockOut of stock
Easy peel and stick application
Etched foil heating element for optimal heat transfer and long life.
Durable silicone/fiberglass cover resists abrasion.
120 V models are assembled with a standard 6’ (1.8m) HPN cord and plug.
240 V models include 6’ (1.8m) HPN cord without plug. -
-
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27 -
AF27993NF Air Filter
د.إ0.000Availability: In stockOut of stock
Features:
■ Nanofibre filter media provides the highest possible engine protection efficiency without compromising filter life
■ Pleat geometry, spacing and stabilization yields maximum filter performance and long life for lower equipment operating costs
■ Proven radial air filter seal ensures reliable fit in the SSG air housing and easy service events
■ Complete Fleetguard system solution including the AF27994 secondary filter and the SP1307 housing service cover -
CLM Model
د.إ0.000Availability: In stockOut of stock
-
Heating Fluid: Engine coolant (50% glycol/50% water
Power: 27-36kW
Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 120°F (50°C)
High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.9 gal (3.5L)
Pump Power: 0.75Hp (0.55kW)
-
-
CL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
- Adjustable 90° – 130° (32°C – 54°C)
- Fixed Thermostat:
Reviews