The HOTSTART DLV is a complete, packaged dual heating system with PT-100 temperature sensors, pump, motor and all required controls. It heats and circulates coolant and lube oil throughout the entire engine and cooling system. This system heats engines up to 300 L displacement. Forced circulation of the fluid delivers uniform heating throughout the entire engine, enhances equipment availability and decreases wear and tear from cold starts.
DLV System
د.إ0.000
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27
| Product Type | Genset |
|---|---|
| Power (Heater) | |
| Combined Coolant & Oil Heater | Coolant/Lube Oil Heating System |
| Power (Oil Heater) | 12 KW, 6 KW, 9 KW |
QR Code

Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
TPS Model
د.إ0.000Availability: In stockOut of stock
- Application:
The TPS engine pre-heater is designed to pre-heat diesel and gas engines in genset, heavy duty mobile equipment, marine and industrial applications.
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable Thermostat 90–130 °F (32–54 °C)
Voltage Range: 120 and 240 V -
WF 2073 Water Filter
د.إ0.000Availability: In stockOut of stock
WF2073
Media Type: Cellulose 60 23
Micron Rating: 60
Coolant Additive: 23 Units
Overall Height inch (mm): 5.43 (137.92)
Thread Size: 11/16-16 UN- 2B -
CTM Model
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CTM was developed to preheat diesel and gas engines for stationary land power, marine and construction equipment.
-
OCLA System
د.إ0.000Availability: In stockOut of stock
SPECIFICATIONS
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 230, 400 V
Temperature Controller: Adjustable 0 – 100 °C (32 – 212 °F)
Temperature Setting: Oil 40 °C (105 °F) / Coolant 50 °C (120 °F)
High-Limit Temperature Control: Adjustable 0 – 100 °C (32 – 212°F)
High-Limit Temperature Setting: 90 °C (195 °F)
Fluid Capacity: 3.8 L (1 gal)
Pump Power: Oil 0.75 – 2.25 kW (1 – 3 Hp)
Coolant 0.75 kW (1 Hp) -
WL Model
د.إ0.000Availability: In stockOut of stock
HOTSTART tank style engine heaters were developed to pre-heat diesel and gas engines for stationary land power, heavy duty mobile equipment, marine and offshore equipment.
-
EE Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C
Adjustable 90° – 130° (32°C – 54°C)
-
SL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
Adjustable 90° – 130°F (32°C – 54°C)
-
OCLE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 208, 240, 440 – 480, 575 – 600 V
Temperature Controller: Adjustable 32 – 212 °F (0 – 100 °C)
Temperature Setting: Oil 105 °F (40 °C) / Coolant 120 °F (50 °C)
High-Limit Temperature Control: Adjustable 32–212 °F (0 – 100 °C)
High-Limit Temperature Setting: 195 °F (90 °C)
Fluid Capacity: 1 gal (3.8 L)
Pump Power: Oil 1 – 3 Hp (0.75 – 2.25 kW) Coolant 1 Hp (0.75 kW)
Maximum Pressure: 100 psi (690 kPa) -
CMM Model
د.إ0.000Availability: In stockOut of stock
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Power: 12 – 24kW
- Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
- Temperature Controller: Adjustable 32°-212°F (0°-100°C)
- Temperature Setting: 120°F (50°C)
- High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
- High Limit Temperature Setting: 195°F (90°C)
- Fluid Capacity: 0.8 gal (3.0L)
- Pump Power: 0.5Hp (0.37kW)