HOTSTART’s OSX is a complete oil heating system designed to heat and circulate oil in small compressors. The OSX is also designed to prelube the compressor frame in applications with flow requirements up to 11GPM.
The heating system pulls oil from the compressor sump using a positive displacement oil pump. Oil is heated and circulated through the compressor lubricating system.
This eliminates the need for a supplemental prelube pump. Prelubing compressors with heated oil reduces condensation and supplies consistent pressure to the lubricating system with minimal variation in viscosity.
Compressors can benefit from prelubing in both cold climates and high humidity climates where temperature variations can result in damaging condensation.
OSX Model
د.إ0.000
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 240V/60Hz/1ph, 480V/60Hz/3ph (Contact TCT for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 1, 2Hp (0.75, 1.5 kW)
Product Type | Genset |
---|---|
Power (Heater) | |
Oil Heater |
QR Code
Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
WF 2073 Water Filter
د.إ0.000Availability: In stockOut of stock
WF2073
Media Type: Cellulose 60 23
Micron Rating: 60
Coolant Additive: 23 Units
Overall Height inch (mm): 5.43 (137.92)
Thread Size: 11/16-16 UN- 2B -
Battery Wraps
د.إ0.000Availability: In stockOut of stock
Prolong the life of your battery with HOTSTART thermal battery wraps with or without thermostat.
• Durable, fire-retardant vinyl cover that resists oils and acids.
• All standard battery pads and battery wraps come with 6’ (1.8m) grounded cord and plug.
• Fast, easy installation.
• Boosts battery cranking power as much as 75%. -
CSM Style A
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CSM was developed to preheat diesel and gas engines for stationary land power, marine, large mining and construction equipment.
-
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27 -
OSM Model
د.إ0.000Availability: In stockOut of stock
Primary Heating Fluid: Engine Oil
Heat Power: 1, 2, 3 kW
Voltage Range: 1 or 3 Phase 120-690V (50 or 60Hz)
Temperature Controller: Fixed 80°-100°F (27°-38°C)
High-Limit Temp. Control: Fixed 165°-205°F (74°-96°C)
Fluid Capacity: Oil – 0.6 gal (2.2L)
Pump Power: 0.33 Hp (.25 kW) -
CTM Model
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CTM was developed to preheat diesel and gas engines for stationary land power, marine and construction equipment.
-
SB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable 90° – 130°F (32°C – 54°C)
-
OCLA System
د.إ0.000Availability: In stockOut of stock
SPECIFICATIONS
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 230, 400 V
Temperature Controller: Adjustable 0 – 100 °C (32 – 212 °F)
Temperature Setting: Oil 40 °C (105 °F) / Coolant 50 °C (120 °F)
High-Limit Temperature Control: Adjustable 0 – 100 °C (32 – 212°F)
High-Limit Temperature Setting: 90 °C (195 °F)
Fluid Capacity: 3.8 L (1 gal)
Pump Power: Oil 0.75 – 2.25 kW (1 – 3 Hp)
Coolant 0.75 kW (1 Hp) -
COL Model
د.إ0.000Availability: In stockOut of stock
COL System Features
Weathertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
Flow detection switches for fail-safe operation
Pressure switch for automatic operation
Universal mounting for varied mounting configurations
100° to 120°F thermostat for coolant and 80° to 100°F oil thermostat
On/Off switch for coolant and oil heating operations