HOTSTART’s OCLA is a complete oil and coolant heating system for international oil and gas applications. The OCLA heats oil capacities up to 1350L (355 gal.) and heats coolant in engines up to 300L (18,300CID) depending on application and ambient temperature. The OCLA provides uniform heating to the oil throughout the engine oil sump and external piping, enhancing compressor availability. The unit also provides uniform coolant heating to the engine, reducing condensation in the engine block and cylinders that occurs with temperature variation.
OCLA System
د.إ0.000
SPECIFICATIONS
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 230, 400 V
Temperature Controller: Adjustable 0 – 100 °C (32 – 212 °F)
Temperature Setting: Oil 40 °C (105 °F) / Coolant 50 °C (120 °F)
High-Limit Temperature Control: Adjustable 0 – 100 °C (32 – 212°F)
High-Limit Temperature Setting: 90 °C (195 °F)
Fluid Capacity: 3.8 L (1 gal)
Pump Power: Oil 0.75 – 2.25 kW (1 – 3 Hp)
Coolant 0.75 kW (1 Hp)
Product Type | Genset |
---|---|
Combined Coolant & Oil Heater | Coolant & Oil Heating System |
Power (Oil Heater) | 12 KW, 2.5 KW |
Power (Heater) |
QR Code

Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
DLV System
د.إ0.000Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27 -
SL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
Adjustable 90° – 130°F (32°C – 54°C)
-
OCLE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 208, 240, 440 – 480, 575 – 600 V
Temperature Controller: Adjustable 32 – 212 °F (0 – 100 °C)
Temperature Setting: Oil 105 °F (40 °C) / Coolant 120 °F (50 °C)
High-Limit Temperature Control: Adjustable 32–212 °F (0 – 100 °C)
High-Limit Temperature Setting: 195 °F (90 °C)
Fluid Capacity: 1 gal (3.8 L)
Pump Power: Oil 1 – 3 Hp (0.75 – 2.25 kW) Coolant 1 Hp (0.75 kW)
Maximum Pressure: 100 psi (690 kPa) -
AF27993NF Air Filter
د.إ0.000Availability: In stockOut of stock
Features:
■ Nanofibre filter media provides the highest possible engine protection efficiency without compromising filter life
■ Pleat geometry, spacing and stabilization yields maximum filter performance and long life for lower equipment operating costs
■ Proven radial air filter seal ensures reliable fit in the SSG air housing and easy service events
■ Complete Fleetguard system solution including the AF27994 secondary filter and the SP1307 housing service cover -
-
CB Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
-
OSM Model
د.إ0.000Availability: In stockOut of stock
Primary Heating Fluid: Engine Oil
Heat Power: 1, 2, 3 kW
Voltage Range: 1 or 3 Phase 120-690V (50 or 60Hz)
Temperature Controller: Fixed 80°-100°F (27°-38°C)
High-Limit Temp. Control: Fixed 165°-205°F (74°-96°C)
Fluid Capacity: Oil – 0.6 gal (2.2L)
Pump Power: 0.33 Hp (.25 kW) -
CMM Model
د.إ0.000Availability: In stockOut of stock
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Power: 12 – 24kW
- Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
- Temperature Controller: Adjustable 32°-212°F (0°-100°C)
- Temperature Setting: 120°F (50°C)
- High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
- High Limit Temperature Setting: 195°F (90°C)
- Fluid Capacity: 0.8 gal (3.0L)
- Pump Power: 0.5Hp (0.37kW)
-
OCSM Model
د.إ0.000Availability: In stockOut of stock
- Primary Heating Fluid: Engine Coolant
- Secondary Heating Fluid: Engine Oil
- Heat Power: 6, 9, 12 kW
- Voltage Range: 1 or 3 Phase 208 – 600V (50 or 60 Hz)
- Temperature Controller: Fixed 100 – 120 °F (38 – 49 °C)
- High-Limit Temp. Control: Fixed 165 – 205 °F (74 – 96 °C)
- Fluid Capacity: Coolant – 0.7 gal (2.6L)
- Oil – 0.2 gal (0.8L)
- Pump Power: Coolant – 0.04 Hp (0.03 kW)
- Oil – 0.33 Hp (0.25 kW)