Use a thermostat with all lube oil heaters to protect the oil from overheating. Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times.
Lube Oil Heater (Weathertight)
د.إ0.000
Temperature Range | Code | |
ON | OFF | |
60°F (16C) | 80°F (27C) | 6 |
80°F (27C) | 100°F(38C) | 8 |
100°F(38C) | 120°F (49C) | 10 |
Power (Heater) | 50 Watts, 75 Watts, 125 Watts, 150 Watts, 225 Watts, 300 Watts, 450 Watts, 500 Watts |
---|---|
Oil Heater | |
Product Type | Genset |
QR Code
Related Products
- desktop-columns-3 tablet-columns-2 mobile-columns-1
-
CL Model (Watertight)
د.إ0.000Availability: In stockOut of stock
Pressure switch or relay for automatic operation
Universal mounting for varied mounting configuration
100° to 120°F fixed thermostats
On/Off switch for manual control
Watertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
External motor protective switch reset button -
WL Model
د.إ0.000Availability: In stockOut of stock
HOTSTART tank style engine heaters were developed to pre-heat diesel and gas engines for stationary land power, heavy duty mobile equipment, marine and offshore equipment.
-
OSX Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 240V/60Hz/1ph, 480V/60Hz/3ph (Contact TCT for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 1, 2Hp (0.75, 1.5 kW) -
AF27993NF Air Filter
د.إ0.000Availability: In stockOut of stock
Features:
■ Nanofibre filter media provides the highest possible engine protection efficiency without compromising filter life
■ Pleat geometry, spacing and stabilization yields maximum filter performance and long life for lower equipment operating costs
■ Proven radial air filter seal ensures reliable fit in the SSG air housing and easy service events
■ Complete Fleetguard system solution including the AF27994 secondary filter and the SP1307 housing service cover -
OSE Model
د.إ0.000Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 480V/60Hz/3ph (Contact HOTSTART for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 0.75, 2Hp (0.56, 1.5 kW) -
-
CSM Style B
د.إ0.000Availability: In stockOut of stock
HOTflow™ model CSM was developed to preheat diesel and gas engines for stationary land power, marine, large mining and construction equipment.
-
CL Model
د.إ0.000Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
- Adjustable 90° – 130° (32°C – 54°C)
- Fixed Thermostat:
-
CMM Model
د.إ0.000Availability: In stockOut of stock
- Heating Fluid: Engine coolant (50% glycol/50% water)
- Power: 12 – 24kW
- Rated Voltage: 400V/50Hz/3ph, 440V/60Hz/3ph, 690V/50&60Hz/3ph
- Temperature Controller: Adjustable 32°-212°F (0°-100°C)
- Temperature Setting: 120°F (50°C)
- High Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
- High Limit Temperature Setting: 195°F (90°C)
- Fluid Capacity: 0.8 gal (3.0L)
- Pump Power: 0.5Hp (0.37kW)
Reviews