- Features:
- UL-C/US listed
- CE compliant
- Various temperature settings available, including adjustable thermostat 90–130 °F (32–54 °C)
- Available with UL 120 or 240 V plug or CE 240 V plug
د.إ0.000
The TPS engine pre-heater is designed to pre-heat diesel and gas engines in genset, heavy duty mobile equipment, marine and industrial applications.
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable Thermostat 90–130 °F (32–54 °C)
Voltage Range: 120 and 240 V
3 Range Model:
This high-impact plastic tank engine heater offers exceptional tensile strength and resists corrosion. The compact design is ideal for locations that require minimal mounting space. Thermostatically controlled and designed for efficient heating, this model is available from 500 watt to 2000 watt for engines of 150 CID to 700 CID.

Availability: In stockOut of stock
Heating Fluid: Oil/Coolant
Heat Power: Oil 2.5 – 12 kW / Coolant 6 – 36 kW
Voltage Range: 208, 240, 440 – 480, 575 – 600 V
Temperature Controller: Adjustable 32 – 212 °F (0 – 100 °C)
Temperature Setting: Oil 105 °F (40 °C) / Coolant 120 °F (50 °C)
High-Limit Temperature Control: Adjustable 32–212 °F (0 – 100 °C)
High-Limit Temperature Setting: 195 °F (90 °C)
Fluid Capacity: 1 gal (3.8 L)
Pump Power: Oil 1 – 3 Hp (0.75 – 2.25 kW) Coolant 1 Hp (0.75 kW)
Maximum Pressure: 100 psi (690 kPa)
Availability: In stockOut of stock
3 Range Model:
- Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)
Availability: In stockOut of stock
3 Range Model:
Fixed Thermostat:
80–100 °F (24–38°C)
100–120 °F (38–49 °C)
120–140 °F (49–60 °C)Adjustable 90° – 130°F (32°C – 54°C)
Availability: In stockOut of stock
Specification:
Heating Fluid: Coolant and Oil
Coolant Heat Power: 18 – 30 kW
Oil Heat Power: 6 – 12 kW
Rated Voltage: 208, 240, 480, 575 V (3Ø 60 Hz)
220, 380, 400, 415 V (3Ø 50 Hz)
Temp Controller, coolant: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 122 °F (50 °C)
Temp Controller, oil: Adj. 32 – 212 °F (0 – 100 °C), preset from factory at 104 °F (40 °C)
High-Limit Temperature Protection
Main Control Box Ingress Protection: NEMA 4 IP66
Coolant Motor Ingress Protection: IP55
Oil Motor Ingress Protection: IP55
Meets Vibration Specification IEC 60068-2-64
Meets Shock Specification IEC 60068-2-27
Availability: In stockOut of stock
Pressure switch or relay for automatic operation
Universal mounting for varied mounting configuration
100° to 120°F fixed thermostats
On/Off switch for manual control
Watertight components rated NEMA 12
Viton mechanical seal pumps for extended seal life and temperatures to 350°F
External motor protective switch reset button
Availability: In stockOut of stock
| TEMPERATURE RANGE | CONTROL | |
| ON | OFF | |
| 60°F (16C) | 80°F (27C) | HLC-6 |
| 80°F (27C) | 100°F (38C) | HLC-8 |
| 100°F (38C) | 120°F (49C) | HLC-10 |
| ELECTRICAL RATING | ||
| 15 Amps at 120 Vac | ||
| 10 Amps at 240 Vac | ||
| 10 Amps at 277 Vac | ||
Availability: In stockOut of stock
Availability: In stockOut of stock
Primary Heating Fluid: Engine Oil
Heat Power: 1, 2, 3 kW
Voltage Range: 1 or 3 Phase 120-690V (50 or 60Hz)
Temperature Controller: Fixed 80°-100°F (27°-38°C)
High-Limit Temp. Control: Fixed 165°-205°F (74°-96°C)
Fluid Capacity: Oil – 0.6 gal (2.2L)
Pump Power: 0.33 Hp (.25 kW)
Availability: In stockOut of stock
Heating Fluid: Oil
Heat Power: 1.5, 2.5 kW
Voltage Range: 480V/60Hz/3ph (Contact HOTSTART for other voltage requirements)
Temperature Controller: Adjustable 32°-212°F (0°-100°C)
Temperature Setting: 105°F (40°C)
High-Limit Temperature Control: Adj. 32°-212°F (0°-100°C)
High-Limit Temperature Setting: 195°F (90°C)
Fluid Capacity: 0.6 gal (2.2L)
Pump Power: 0.75, 2Hp (0.56, 1.5 kW)